Split-core current transformer RCT-RJ11 (0–1000 A) for CTH01
Vendors's code:
Product code: RCT-1000
Barcode:
Code 39:
ISBN:
Milesight RCT-1000 is a split-core current transformer Split-Core CT designed for use with the energy monitoring hub Milesight CTH01. The RCT-1000 variant enables current measurement in the range 0–1000 A, offers accuracy class 0.5 and has a measurement opening with a diameter of Ø51 mm.
The split-core design allows the transformer to be installed around an existing conductor without cutting it, while the RJ11 connection allows the sensor to be connected directly to one of the 12 CTH01 current channels. The transformer is designed for monitoring high loads, main supply circuits, distribution boards and industrial installations.
Shipping costs are not included in the price.
Shipping costs are not included in the price.
Opis
Produkty powiązane
RCT-1000 — split-core current transformer for Milesight CTH01
Milesight RCT-1000 is a Split-Core CT designed for current measurement from 0 to 1000 A in combination with the Milesight CTH01 Smart Power Monitor hub.
The clamp-on design enables installation of the transformer around an existing conductor without cutting it or routing the conductor through a closed core.
RCT-1000 is intended primarily for high loads, main power circuits, distribution boards, industrial installations, HVAC systems, UPS systems and other circuits requiring current monitoring up to 1000 A.
Up to 1000 A, class 0.5 and non-invasive installation
0–1000 A
The wide measurement range enables monitoring of high loads and main supply circuits.
Class 0.5
The transformer has accuracy class 0.5 for reliable current monitoring.
Split-Core
The split core simplifies installation on an existing conductor without cutting it.
Monitoring of high loads and power installations
Current measurement from 0 to 1000 A
RCT-1000 is the largest standard split-core current transformer variant designed for CTH01.
The 0–1000 A range allows it to be used in circuits with significantly higher loads than the RCT-100, RCT-300 and RCT-500 variants.
Installation without cutting the monitored conductor
The Split-Core design allows the core to be opened, placed around the monitored conductor and closed again.
The solution significantly simplifies retrofit of existing distribution boards and installations because the conductor does not need to be routed through a closed transformer.
Ø51 mm for large-cross-section conductors
RCT-1000 has a measurement opening with a diameter of 51 mm.
The large opening enables it to fit around conductors used in high-current installations.
Direct RJ11 connection
RCT-1000 is designed as a measurement accessory for the Milesight CTH01 Smart Power Monitor Hub.
The transformer uses an RJ11 connection and can be connected to one of the 12 current measurement channels available in CTH01.
Each CTH01 channel can be configured according to the transformer range used, enabling different CT ranges to be combined in one installation.
Up to 12 current channels in one CTH01
Milesight CTH01 has 12 independent inputs for current transformers.
This allows monitoring of up to 12 single-phase circuits, up to 4 three-phase circuits, or configuration of a mixed system.
RCT-1000 can be used together with other compatible transformer ranges depending on the parameters of individual circuits.
Part of a complete electrical parameter monitoring system
After RCT-1000 is connected to CTH01, current data can be used by the hub to calculate energy parameters.
CTH01 supports, among other functions, RMS current and voltage measurement, active, reactive and apparent power, energy, power factor and harmonic analysis.
This allows RCT-1000 to be part of a solution for monitoring energy consumption, power quality and electrical installation load.
Design suitable for distribution boards and industrial installations
Transformer for conductors up to Ø51 mm
Ø51 mm
The large core opening enables installation on large-cross-section conductors.
835 g
The RCT-1000 transformer weighs approximately 835 grams.
UL94 V0
The enclosure uses material with a high flame-retardancy rating.
1000 A variant for the largest standard CTH01 loads
The transformer range should be selected according to the maximum expected current of the monitored circuit.