RG 200 TB Pro Tipping Bucket Rain Gauge Ø200 mm
Vendors's code:
Product code: RG200TB-PRO
Barcode:
Code 39:
ISBN:
IoT Solution RG 200 TB is a professional tipping bucket rain gauge designed to measure the amount, intensity, and duration of precipitation. Equipped with a Ø200 mm collecting inlet, a tipping bucket mechanism, and an AISI 304 stainless steel housing.
Available resolutions of 0.1 / 0.2 / 0.5 mm and versions with pulse output, RS485 Modbus RTU, 4–20 mA, and voltage outputs enable integration with automation and environmental monitoring systems.
Shipping costs are not included in the price.
Shipping costs are not included in the price.
Opis
Produkty powiązane
The RG 200 TB tipping-bucket rain gauge measures rainfall accumulation, intensity and duration. Its Ø200 mm inlet, low-friction tipping-bucket mechanism and AISI 304 stainless steel housing make it suitable for automated environmental monitoring.
How Does the RG 200 TB Rain Gauge Work?
Rainwater enters through the Ø200 mm inlet into a funnel and then flows into a two-compartment tipping bucket. When one compartment fills, the mechanism tips, discharges the collected water and generates a measurement event. Each tip corresponds to a specific rainfall depth: 0.1 mm, 0.2 mm or 0.5 mm, depending on the model ordered.
The streamlined, three-dimensional tipping bucket moves smoothly and is self-cleaning, helping remove dust. The design complies with the requirements of standard GB/T 21978.2-2014, with an expected service life of more than 7 years.
Applications
Features and Benefits
Full Technical Specifications
| PARAMETER | VALUE |
|---|---|
| MEASUREMENT | |
| Inlet Diameter | Ø200 mm |
| Inlet Edge Angle | 40°–45° |
| Measurement Range | 0–100 mm/day (default); max. 6553.5 mm/day |
| Resolution | 0.1 / 0.2 / 0.5 mm; selectable when ordering |
| Rainfall Intensity | 0.01–4 mm/min; maximum permissible intensity 8 mm/min |
| Accuracy | ≤ ±3% |
| POWER SUPPLY AND COMMUNICATION | |
| Supply Voltage | 5–24 V DC (RS485, 0–2 V); 12–24 V DC (0–5 V, 0–10 V, 4–20 mA) |
| Power Consumption | ≤ 0.2 W |
| Protocol (RS485) | Modbus RTU; default address: 01 |
| Additional Functions | Internal clock, up to 10 registers |
| CONSTRUCTION AND ENVIRONMENT | |
| Housing Material | AISI 304 stainless steel |
| Height | 335 mm |
| Operating Temperature | 0°C … +50°C |
| Operating Humidity | < 95% RH |
| Standard | GB/T 21978.2-2014 |
Models and Signal Outputs
Choose the version compatible with your controller or data logger input: pulse, digital RS485/Modbus RTU, 4–20 mA current or voltage output. The resolution is specified in the ordering code.
Ordering Code
Example: RG 200 TB Impuls Pro-02 – pulse output, 0.2 mm/pulse. Measurement ranges other than 0–100 mm/day are available on request.
Foundation Mounting
Important: the power supply parameters and communication interface depend on the selected model. The model variant and measurement resolution must be specified when ordering. Technical specifications are subject to change.