EEM-MA771 - Meter

Phoenix Contact EEM-MA771 2908286 is a multifunction energy meter from the EMpro family designed for measurement of electrical parameters in low-voltage installations up to 690 V AC. The device enables direct connection of Rogowski coils, supports current measurement up to 400 A or 4000 A, performs continuous True RMS measurement and analyzes harmonics up to the 63rd harmonic.

The meter has Ethernet 10/100 Mb/s with Modbus TCP and REST, a backlit, two-color LCD display, and a 24 V DC digital input and output. Voltage measurement accuracy is 0,2%, current 0.5%, active energy meets class 1 according to IEC 62053-21, and the 96 × 96 mm panel enclosure is designed for installation in the front panel of a distribution board.

Go to full description
Availability:
In Stock
Shipping time: 31 dni
USD EUR with VAT without VAT
Price $593.41
incl. 23% VAT

Shipping costs are not included in the price.

szt.

Opis

Produkty powiązane

EEM-MA771 — panel-mounted EMpro energy meter

Phoenix Contact EEM-MA771 2908286 is a multifunction energy meter designed to measure and monitor electrical parameters in low-voltage installations up to 690 V AC.

The device enables direct connection of Rogowski coils, performs continuous True RMS measurement, and allows analysis of voltage, current, power, energy and higher harmonics.

EEM-MA771 combines a panel-mounted design with a local display and Ethernet with Modbus TCP and REST, enabling both convenient on-site parameter reading and data transmission to higher-level control and energy management systems.

Up to 4000 A, Rogowski coils and Ethernet communication

4000 A

The second measurement range enables monitoring of high current loads up to 4000 A.

Rogowski

Direct inputs for Rogowski coils simplify installation and reduce the number of additional components in the measurement circuit.

Modbus TCP

10/100 Mb/s Ethernet enables fast data transmission to automation and energy management systems.

Monitoring of high loads and power installations

Main distribution boards
Industrial plants
Process lines
HVAC systems
Data centers
High energy loads
Energy monitoring
Facility Management

Direct current measurement up to 4000 A

EEM-MA771 has three measurement inputs RC1, RC2 and RC3 designed for direct connection of Rogowski coils.

The device supports two measurement ranges: up to 400 A and up to 4000 A, allowing the configuration to be adapted to different installation load levels.

When using a Phoenix Contact coil, the transmission ratio is 100 mV / 1000 A, while the voltage range of the measurement input is from 500 µV to 400 mV.

Current inputs
RC1 / RC2 / RC3
Level 1
up to 400 A
Level 2
up to 4000 A
Current accuracy
0,5%

Measurement without conventional 1 A / 5 A current transformers

Rogowski coils can be installed around existing conductors or busbars, making it easier to expand measurement systems already in operation.

This solution is particularly well suited to high-current installations and locations where conventional current transformers would be difficult to use.

The direct inputs of EEM-MA771 reduce the number of components between the coil and the meter, reducing additional wiring.

Continuous true RMS measurement

EEM-MA771 can operate in three-phase 3- and 4-wire, two-phase and single-phase installations.

All electrical parameters are measured according to the True RMS continuously, allowing the device to correctly represent distorted voltage and current waveforms as well.

The fundamental frequency range is from 45 to 65 Hz.

Measurement principle
True RMS
Frequency
45–65 Hz
Sampling 50 Hz
12,8 kHz
Sampling 60 Hz
15,4 kHz

Direct measurement up to 690 V AC

The meter has three voltage inputs V1, V2 and V3 designed to monitor individual installation phases.

The direct measurement range is 18–690 V AC phase-to-phase and 11–400 V AC phase-to-neutral.

With external voltage transformers, the primary voltage can be configured from 60 V AC to 2,000,000 V AC.

Phase–phase
18–690 V AC
Phase–N
11–400 V AC
Accuracy
0,2%

Class 1 for active energy

Voltage measurement accuracy is 0,2%, while current measurement using Rogowski coils is performed with 0.5% accuracy.

Power measurement accuracy is 1%, and active energy meets the requirements of class 1 according to IEC 62053-21.

Reactive energy is measured in class 2 according to IEC 62053-23.

Voltage
0,2%
Current
0,5%
Power
1%
Active energy
Class 1
Reactive energy
Class 2

Recording up to the 63rd harmonic

EEM-MA771 enables analysis of voltage and current harmonics up to the 63rd harmonic.

This function makes it possible to identify distortions associated with inverters, variable-speed drives, switched-mode power supplies and other nonlinear loads.

Harmonic data can support installation diagnostics and analysis of power quality parameters.

Ethernet with Modbus TCP and REST

EEM-MA771 has one Ethernet RJ45 supporting transmission at 10 or 100 Mb/s.

Modbus TCP enables direct transmission of measurement values to PLCs, SCADA systems, BMS and energy management systems.

Interface REST also makes it possible to provide data to applications and IT systems without using serial communication.

Interface
Ethernet RJ45
Ethernet
10 / 100 Mb/s
Protocol
Modbus TCP
API
REST

Digital I/O for automation integration

The meter has one digital input compliant with IEC/EN 61131-2 Type 3.

The input operates with a 24 V DC signal, while the input voltage range is from 0 to 30 V DC.

One 24 V DC digital output is also available with a maximum current of 100 mA.

Digital input
1 × 24 V DC
Input range
0–30 V DC
Digital output
1 × 24 V DC
Output current
≤100 mA

Wide AC and DC supply range

EEM-MA771 can be powered by AC or DC voltage, making it easier to adapt the device to the infrastructure available in the distribution board.

The supply range is 100–400 V AC ±20% or 150–250 V DC ±20%.

The meter's power consumption does not exceed 4 W.

AC power supply
100–400 V AC
±20%
DC power supply
150–250 V DC
±20%
Power consumption
≤4 W

LCD display and configuration via web server

EEM-MA771 has a backlit, two-color, multi-line LCD display enabling local viewing of the most important installation parameters.

The integrated web server allows the device to be configured from a standard web browser.

An intuitive installation wizard guides the user through the basic settings of network topology, measurement parameters and communication.

Reinforced insulation and 4 kV AC test voltage

The EEM-MA771 design provides electrical insulation in accordance with IEC 61010-1 and IEC 61010-2-030 requirements.

It uses reinforced insulation, and the test voltage is 4 kV AC for 60 seconds.

For the voltage measurement input, measurement category III at 300 V AC and II at 600 V AC is specified.

Operation at temperatures from −25 to +70°C

Operating temperature
−25…+70°C
Storage temperature
−30…+80°C
Humidity
≤95%
non-condensing
Operating altitude
≤2000 m

96 × 96 mm panel meter

EEM-MA771 is designed for installation in the front panel of a distribution board or control cabinet.

The device dimensions are 96 × 96 × 73.3 mm, while the required installation depth is 58.3 mm.

The enclosure has an IP20 protection rating, while the front with display and supplied gasket achieves IP54.

96 × 96 mm

The standard panel design enables installation in typical distribution boards and control cabinets.

IP54

The device front with the gasket fitted provides an increased protection rating.

58,3 mm

The small installation depth facilitates panel installation of the meter.

Key parameters of Phoenix Contact EEM-MA771

Manufacturer
Phoenix Contact
Model
EEM-MA771
Catalog number
2908286
Family
EMpro
Current measurement
Rogowski coils
Current range
up to 400 A / 4000 A
Current accuracy
0,5%
Phase-to-phase voltage
18–690 V AC
Phase-to-neutral voltage
11–400 V AC
Voltage accuracy
0,2%
Power accuracy
1%
Active energy
class 1
Reactive energy
class 2
Harmonics
up to the 63rd
Ethernet
RJ45, 10 / 100 Mb/s
Communication
Modbus TCP / REST
Digital input
1 × 24 V DC
Digital output
1 × 24 V DC / ≤100 mA
AC power supply
100–400 V AC ±20%
DC power supply
150–250 V DC ±20%
Power consumption
≤4 W
Display
LCD, backlit, 2-color
Test voltage
4 kV AC
50 Hz, 60 s
Operating temperature
−25…+70°C
Storage temperature
−30…+80°C
Protection rating
IP20 / IP54 front
Dimensions
96 × 96 × 73,3 mm
Installation depth
58,3 mm
Mounting
front panel

EEM-MA771 in an energy monitoring system

Rogowski coils
current measurement up to 4000 A
→
EEM-MA771
energy measurement and analysis
→
Ethernet
Modbus TCP / REST
→
Higher-level system
energy monitoring and management
MODEL 3D

EEM-MA771 - Meter

Ładowanie modelu 3D

Nowości

  • Bestseller New Product
    obraz_2026-07-14_113033157.png GS601 (1).png
    Product code GS601-868M

    E-cigarette smoke sensor

    Manufacturer Milesight
    Gross price $270.60
    incl. %s VAT
    Net price $220.00
    without 23% VAT