EEM-MA371-R - Meter

Phoenix Contact EEM-MA371-R 2907985 is a multifunction energy meter from the EMpro family designed for measurement of electrical parameters in low-voltage installations up to 690 V AC. The device enables direct connection of Rogowski coils and supports current measurement ranges up to 400 A or 4000 A, performs continuous True RMS measurement and analyzes harmonics up to the 63rd harmonic.

The meter has 10/100 Mb/s Ethernet with Modbus TCP and REST API plus RS-485 with Modbus RTU, allowing integration with both networked and serial automation systems. Voltage measurement accuracy is 0,2%, current 0.5%, active energy meets class 1 according to IEC 62053-21, and the operating temperature range is −25…+70°C.

Go to full description
Availability:
In Stock
Shipping time: 31 dni
USD EUR with VAT without VAT
Price $608.64
incl. 23% VAT

Shipping costs are not included in the price.

szt.

Opis

Produkty powiązane

EEM-MA371-R — EMpro energy meter with direct Rogowski input

Phoenix Contact EEM-MA371-R 2907985 is a multifunction energy meter designed to monitor electrical parameters in low-voltage installations up to 690 V AC.

The device supports single-, two- and three-phase installations, performs continuous True RMS measurement and allows monitoring of voltage, current, power, energy and higher harmonics.

EEM-MA371-R enables direct connection of Rogowski coils and combines two communication standards: Ethernet with Modbus TCP and REST API, and RS-485 with Modbus RTU. This allows it to be used both in new energy monitoring systems and when retrofitting existing automation installations.

Up to 4000 A, Rogowski coils and two Modbus interfaces

4000 A

The second measurement range enables current monitoring up to 4000 A using a suitable Rogowski coil.

Rogowski

Direct inputs for Rogowski coils reduce the number of additional components required in the measurement circuit.

RTU / TCP

Ethernet and RS-485 enable integration of the device with systems using Modbus TCP and Modbus RTU.

Monitoring of high loads and power installations

Main distribution boards
Industrial plants
Process lines
HVAC systems
Data centers
High energy loads
Energy monitoring
Facility Management

Direct current measurement up to 4000 A

EEM-MA371-R has three measurement inputs RC1, RC2 and RC3 designed for direct connection of Rogowski coils.

The device supports two measurement levels: up to 400 A and up to 4000 A, allowing it to be used for both standard circuits and high-energy loads.

When using a Phoenix Contact coil, the transmission factor is 100 mV / 1000 A, and the input voltage range of the measurement path is from 500 µV to 400 mV.

Current inputs
RC1 / RC2 / RC3
Level 1
up to 400 A
Level 2
up to 4000 A
Current accuracy
0,5%

Measurement without disconnecting the main current path

Rogowski coils can be installed around existing conductors or busbars without having to route the conductor through the closed core of a conventional transformer.

This solution is particularly well suited to expansion and retrofit of existing distribution boards and installations where access to the main current paths is limited.

Direct connection of the coils to EEM-MA371-R also reduces the number of additional measurement components and simplifies wiring.

Continuous True RMS measurement

EEM-MA371-R is suitable for operation in three-phase 3- and 4-wire networks, two-phase networks and single-phase networks.

All values are measured according to the principle of continuous True RMS measurement, allowing distorted voltage and current waveforms to be analyzed correctly as well.

The fundamental frequency range is from 45 to 65 Hz.

Measurement principle
True RMS
Frequency
45–65 Hz
Sampling 50 Hz
12,8 kHz
Sampling 60 Hz
15,4 kHz

Direct measurement up to 690 V AC

EEM-MA371-R has three voltage inputs V1, V2 and V3 for monitoring the parameters of individual phases.

The direct measurement range is 18–690 V AC phase-to-phase and 11–400 V AC phase-to-neutral.

External voltage transformers can also be used for installations requiring measurement of a higher primary voltage.

Phase–phase
18–690 V AC
Phase–N
11–400 V AC
Accuracy
0,2%

Class 1 for active energy

EEM-MA371-R measures current with an accuracy of 0,5%, while power measurement accuracy is 1%.

Active energy measurement meets the requirements class 1 according to IEC 62053-21.

Reactive energy is measured in class 2 according to IEC 62053-23.

Voltage
0,2%
Current
0,5%
Power
1%
Active energy
Class 1

Recording up to the 63rd harmonic

The meter enables analysis of higher voltage and current harmonics up to the 63rd harmonic.

This makes it possible to identify distortions generated by inverters, variable-speed drives, switched-mode power supplies and other nonlinear loads.

Harmonic information can be used during installation diagnostics, power quality analysis and identification of sources of additional energy losses.

Modbus TCP and REST API

EEM-MA371-R has a Ethernet RJ45 operating at 10 or 100 Mb/s.

Protocol Modbus TCP enables measurement values to be transmitted to PLC controllers, SCADA systems, BMS and energy management systems.

Interface REST API via HTTP also enables integration of the device with applications and IT systems.

Interface
Ethernet RJ45
Ethernet
10 / 100 Mb/s
Protocol
Modbus TCP
API
REST HTTP

Modbus RTU for integration with existing automation

The EEM-MA371-R version has an additional RS-485 with Modbus RTU protocol.

This enables direct connection of the meter to existing serial buses used by controllers, data concentrators and automation systems.

The RS-485 transmission speed can be configured in the range from 2.4 to 115.2 kb/s, and the device has an integrated 120 Ω terminating resistor.

Standard
RS-485
Protocol
Modbus RTU
Speed
2,4–115,2 kb/s
Termination
120 Ω

Digital I/O for automation integration

EEM-MA371-R has one digital input compliant with IEC/EN 61131-2 Type 3.

The input operates with a 24 V DC signal and a voltage range from 0 to 30 V DC.

The device also has one 24 V DC digital output with a maximum current of 100 mA.

Digital input
1 × 24 V DC
Digital output
1 × 24 V DC
Output current
≤100 mA

LCD display and configuration via web server

The meter has backlit, two-color, multi-line LCD display, enabling local viewing of the most important installation parameters.

The integrated web server allows the device to be configured using a standard web browser.

A guided step-by-step installation wizard simplifies configuration of network topology, measurement parameters and communication.

Power supply from AC or DC installation

AC power supply
100–230 V AC
±20%
DC power supply
150–250 V DC
±20%
Power consumption
≤4 W

Operation at temperatures from −25 to +70°C

Operating temperature
−25…+70°C
Storage temperature
−30…+80°C
Humidity
≤95%
non-condensing
Operating altitude
≤2000 m

Compact 5-TE enclosure for DIN rail

EEM-MA371-R is designed for mounting on a horizontal DIN rail in electrical distribution boards and control cabinets.

The enclosure dimensions are 90 × 90 × 71,9 mm and a width corresponding to 5 modules.

The enclosure has an IP20 protection rating, while the display area has an IP40 protection rating.

5 TE

The 90 mm width enables compact installation of the meter in a distribution board.

DIN

The device design is prepared for direct mounting on a horizontal mounting rail.

IP20 / IP40

The enclosure has an IP20 protection rating, while the display section has IP40.

Key parameters of Phoenix Contact EEM-MA371-R

Manufacturer
Phoenix Contact
Model
EEM-MA371-R
Catalog number
2907985
Family
EMpro
Current measurement
Rogowski coils
Current range
up to 400 A / 4000 A
Current accuracy
0,5%
Phase-to-phase voltage
18–690 V AC
Phase-to-neutral voltage
11–400 V AC
Voltage accuracy
0,2%
Power accuracy
1%
Active energy
class 1
Reactive energy
class 2
Harmonics
up to the 63rd
Ethernet
RJ45, 10 / 100 Mb/s
Ethernet protocols
Modbus TCP / REST HTTP
Serial interface
RS-485
Serial protocol
Modbus RTU
RS-485 speed
2,4–115,2 kb/s
RS-485 termination
120 Ω
AC power supply
100–230 V AC ±20%
DC power supply
150–250 V DC ±20%
Power consumption
≤4 W
Digital input
1 × 24 V DC
Digital output
1 × 24 V DC / ≤100 mA
Display
LCD, backlit, 2-color
Operating temperature
−25…+70°C
Protection rating
IP20 / IP40 display
Dimensions
90 × 90 × 71,9 mm
Modular width
5 TE
Mounting
DIN rail

EEM-MA371-R in an energy monitoring system

Rogowski coils
current measurement up to 4000 A
→
EEM-MA371-R
energy measurement and analysis
→
Modbus TCP / RTU
Ethernet or RS-485
→
Higher-level system
energy monitoring and management
MODEL 3D

EEM-MA371-R - Meter

Ładowanie modelu 3D

Nowości

  • Bestseller New Product
    obraz_2026-07-14_113033157.png GS601 (1).png
    Product code GS601-868M

    E-cigarette smoke sensor

    Manufacturer Milesight
    Gross price $270.60
    incl. %s VAT
    Net price $220.00
    without 23% VAT