Phoenix Contact ECM-UC-10A-UI-REL 1698164 is a configurable current transducer designed for measurement of AC, DC and distorted currents. The device offers four basic measurement ranges 0–0,1 A, 0–1 A, 0–5 A and 0–10 A AC/DC, while the maximum configurable input value is 12,5 A AC/DC. The maximum transmission error is 0,5%, and the measurement bandwidth can reach 1000 Hz.

Version The ECM-UC-10A-UI-REL has a configurable analog voltage or current output, a relay output with one changeover contact and a 24 V DC digital output. Configuration is performed via USB-C and the built-in web interface even without an external power supply. The supply range is 9,6–30 V DC, the device has Push-in terminals and can operate at temperatures −40…+60°C.

Go to full description
Availability:
In Stock
Shipping time: 31 dni
USD EUR with VAT without VAT
Price $547.85
incl. 23% VAT

Shipping costs are not included in the price.

szt.

Opis

Produkty powiązane

ECM-UC-10A-UI-REL — universal current transducer up to 12,5 A

Phoenix Contact ECM-UC-10A-UI-REL 1698164 is a configurable measuring transducer designed for monitoring alternating, direct and distorted currents in automation systems and industrial installations.

The device supports four basic measurement ranges from 0–0,1 A to 0–10 A AC/DC, and the maximum range value can be configured up to 12,5 A AC/DC according to DIN/EN 61010-1.

Version The UI-REL combines a configurable analog voltage or current output with a relay output. This allows one unit to transmit the current measurement value to the control system and independently signal when a configured threshold is exceeded.

One module for measurement, transmission and indication

up to 12.5 A

Configurable ranges allow the transducer to be adapted to circuits with different current values.

U / I

A voltage or current output enables direct operation with standard analog inputs of automation systems.

Relay

The built-in changeover contact enables local indication when a configured current value is exceeded.

Current monitoring in automation and industrial installations

Control cabinets
Electrical distribution boards
Production lines
Drives and motors
AC circuits
DC circuits
Load monitoring
Machine diagnostics

Four ranges from 100 mA to 10 A

The ECM-UC-10A-UI-REL can operate in four basic ranges: 0–0.1 A, 0–1 A, 0–5 A and 0–10 A AC/DC.

The minimum range value can be configured from 0 to 100 mA AC/DC, while the maximum setting according to DIN/EN 61010-1 is 12,5 A AC/DC.

For applications compliant with UL 61010-1, the maximum range is 10 A.

Range 1
0–0,1 A AC/DC
Range 2
0–1 A AC/DC
Range 3
0–5 A AC/DC
Range 4
0–10 A AC/DC
Max. setting
12,5 A AC/DC
DIN/EN 61010-1

Bidirectional DC measurement

For direct current, the device enables measurement of both positive and negative current values.

The standard input range is −10…+10 A DC.

The maximum configuration according to DIN/EN 61010-1 can cover the range −12,5…+12,5 A DC, allowing current-flow direction to be determined as well.

AC, DC and non-sinusoidal signal measurement

The ECM-UC-10A-UI-REL is designed to measure AC, DC and distorted currents.

As a result, it can be used in circuits employing power-electronic equipment, controllers, converters and other loads where the current waveform differs from an ideal sine wave.

The frequency range can be adapted to a specific application.

Configurable bandwidth up to 1000 Hz

The transducer allows several measurement-frequency ranges to be selected.

Available ranges are 0–100 Hz, 0–200 Hz, 0–500 Hz and 0–1000 Hz.

This makes it possible to use the device both in conventional 50/60 Hz installations and in circuits with more complex signal characteristics.

Range 1
0–100 Hz
Range 2
0–200 Hz
Range 3
0–500 Hz
Range 4
0–1000 Hz

Maximum transmission error 0.5%

The maximum transmission error of the ECM-UC-10A-UI-REL is 0,5% of the nominal range value under nominal conditions.

The maximum temperature coefficient is below 0,02%/K.

The parameters provide stable current monitoring even with changes in ambient temperature.

Transmission error
max. 0.5%
Temperature coefficient
<0,02%/K

Response time from 20 ms

The 10–90% step response time during AC/DC measurement is 200 ms.

For DC measurement, the response time can be 20 ms.

This makes it possible to record not only steady values but also relatively fast load changes.

AC/DC response
200 ms
10–90%
DC response
20 ms
10–90%

Resistance to range overload

The ECM-UC-10A-UI-REL has continuous overload capability of 2 × IN.

Surge withstand is 10 × IN, providing additional margin during short-term current increases.

Overload capacity
2 × IN
Surge withstand
10 × IN

Wide selection of standard U/I signals

The measured current value can be transmitted to the control system through a configurable voltage or current output.

Available voltage ranges include 0–10 V, 0–5 V, 1–5 V, 2–10 V, −10…+10 V and −5…+5 V.

For the current signal, available ranges are 0–20 mA and 4–20 mA, as well as reversed characteristics 20–0 mA and 20–4 mA.

Voltage output
0–10 V / 0–5 V / 1–5 V / 2–10 V
Bipolar range
−10…+10 V / −5…+5 V
Current output
0–20 mA / 4–20 mA
U output load
>10 kΩ
I output load
<500 Ω

One changeover contact for local indication

Version UI-REL has a relay with one AgNi alloy changeover contact.

The maximum switching voltage is 250 V AC or 48 V DC.

The permissible continuous contact current is up to 6 A at 250 V AC and up to 1 A at 48 V DC.

Contact type
1 changeover contact
Max. AC voltage
250 V AC
Max. DC voltage
48 V DC
AC current
≤6 A
DC current
≤1 A

Additional 24 V DC signal

The device also provides a digital output signal that can be used to transmit status to the automation system.

The maximum signal voltage is 24 V DC, and the maximum output current is 100 mA.

Output voltage
≤24 V DC
Output current
≤100 mA

USB-C and built-in web interface

The ECM-UC-10A-UI-REL can be configured via the USB-C port and integrated Web Based Management.

During USB-C configuration external 24 V DC power supply is not required, enabling device parameters to be prepared even before installation in the cabinet.

The default WBM interface address is 192.168.128.1.

USB-C

The standard connector enables quick connection of the device to a computer.

WBM

Parameters are configured through an interface launched in a web browser.

Without 24 V DC

For USB-C configuration, the device does not need to be powered from the installation.

Wide range from 9.6 to 30 V DC

The device can be powered in the range 9,6–30 V DC.

The nominal supply range covers 12–24 V DC with −20% / +25% tolerance.

Maximum power consumption is 2.3 W at 30 V DC.

Nominal range
12–24 V DC
Supply range
9,6–30 V DC
Power consumption
≤2,3 W
at 30 V DC

Safe isolation according to IEC/EN 61010-1

The ECM-UC-10A-UI-REL provides safe isolation according to IEC/EN 61010-1.

The test voltage between input and output and between input and power supply is 4 kV AC for 60 seconds.

Between output and power supply, the test voltage is 2 kV AC. The device overvoltage category is III at 300 V.

Fast Push-in terminals

Electrical connections are made using Push-in terminals.

Solid and flexible conductors with cross-section from 0.2 to 2.5 mm².

The recommended stripping length is 10 mm.

Technology
Push-in
Solid conductor
0,2–2,5 mm²
Flexible conductor
0,2–2,5 mm²
AWG
24–13

From −40 to +60°C and altitude up to 4000 m

Operating temperature
−40…+60°C
Storage / transport
−40…+85°C
Humidity
≤95%
non-condensing
Operating altitude
≤4000 m
Protection rating
IP20

Compact housing 22,6 mm wide

The ECM-UC-10A-UI-REL has dimensions of 22,6 × 106,7 × 113,8 mm, so it occupies little space in the control cabinet.

After snapping onto an NS 35/7,5 rail, the device depth is 114,5 mm.

The transducer can be mounted in either vertical or horizontal position. The housing has an IP20 ingress protection rating.

22,6 mm

The narrow design enables efficient use of mounting space.

DIN

The module is prepared for mounting on a standard NS 35/7,5 rail.

IP20

The device is intended for installation in a suitably protected cabinet or distribution board.

Key parameters of Phoenix Contact ECM-UC-10A-UI-REL

Manufacturer
Phoenix Contact
Model
ECM-UC-10A-UI-REL
Catalog number
1698164
Product type
current measurement transducer
Current type
AC / DC / distorted
AC range
0–10 A AC
DC range
−10…+10 A DC
Measurement ranges
0,1 / 1 / 5 / 10 A AC/DC
Max. setting range
12,5 A AC/DC
DIN/EN 61010-1
Frequency
up to 1000 Hz
Transmission error
max. 0.5%
Temperature coefficient
<0,02%/K
AC/DC response
200 ms
DC response
20 ms
Overload capacity
2 × IN
Surge withstand
10 × IN
Current output
0–20 mA / 4–20 mA
Voltage output
m.in. 0–10 V / 0–5 V / 2–10 V / ±10 V
Relay
1 changeover contact
Max. contact voltage
250 V AC / 48 V DC
Max. contact current
6 A AC / 1 A DC
Digital output
24 V DC / ≤100 mA
Configuration
USB-C / WBM
WBM address
192.168.128.1
Supply range
9,6–30 V DC
Power consumption
≤2,3 W
Isolation
safe according to IEC/EN 61010-1
Overvoltage category
III / 300 V
Connections
Push-in
Conductor cross-section
0,2–2,5 mm²
Operating temperature
−40…+60°C
Storage temperature
−40…+85°C
Humidity
≤95%
non-condensing
Operating altitude
≤4000 m
Protection rating
IP20
Dimensions
22,6 × 106,7 × 113,8 mm
Weight
113,5 g
Mounting
vertical or horizontal, DIN rail

ECM-UC-10A-UI-REL in a measurement system

Electrical circuit
AC / DC current up to 12.5 A
→
ECM-UC-10A-UI-REL
current measurement and control
→
U / I signal
e.g. 0–10 V / 4–20 mA
→
PLC / supervisory system
monitoring and control
MODEL 3D

ECM-UC-10A-UI-REL

Ładowanie modelu 3D

Nowości

  • Bestseller New Product
    obraz_2026-07-14_113033157.png GS601 (1).png
    Product code GS601-868M

    E-cigarette smoke sensor

    Manufacturer Milesight
    Gross price $270.60
    incl. %s VAT
    Net price $220.00
    without 23% VAT