Skip to main content
Open search engine
Search
Close search engine Clear Search
English $
Products in the cart: 0. See details
Your cart is empty
Phoenix Contact

EEM-XM357

Phoenix Contact EEM-XM357 1674511 is a three-phase, bidirectional energy meter from the EMpro family, designed for direct current measurement up to 100 A AC. The device records imported and exported energy in four quadrants, supports 4 tariffs and is MID compliant. Active energy is measured in class C according to EN 50470-3 and class 0.5 according to IEC 62053-21.

The meter is equipped with a backlit LCD display, RS-485 with Modbus RTU and 2 passive, optically isolated pulse outputs. The measurement voltage range is 100–277 V AC phase–N and 173–480 V AC phase–phase, Modbus RTU communication supports 2400–38 400 bit/s, and the device is powered directly from the measurement circuit and intended for DIN-rail mounting.

Go to full description
Availability:
In Stock
Shipping time: 31 dni
USD EUR with VAT without VAT
Price $311.50
incl. 23% VAT

Shipping costs are not included in the price.

szt.

Opis

Produkty powiązane

EEM-XM357 — three-phase 100 A energy meter with Modbus RTU

Phoenix Contact EEM-XM357 1674511 is an EMpro family energy meter designed for direct current measurement up to 100 A AC and revenue-grade energy monitoring in single- and three-phase installations.

The device is a bidirectional, meter that records both imported and exported energy. Measurement covers all four quadrants, allowing the direction of active and reactive energy flow to be distinguished.

The EEM-XM357 has RS-485 with Modbus RTU protocol, two pulse outputs and four tariffs controlled via Modbus. Local parameter reading is provided by a backlit LCD display.

Direct 100 A measurement, class C and four tariffs

100 A

The direct current path makes it possible to measure current without external transformers.

Class C / 0.5

High active-energy measurement accuracy according to EN 50470-3 and IEC 62053-21.

4 tariffs

The four tariff registers can be switched and used via Modbus communication.

Energy measurement and billing

Electrical distribution boards
Industrial installations
Commercial buildings
Energy submeters
Internal billing
Consumption monitoring
PLC systems / SCADA
Energy management

Current up to 100 A AC without transformers

The EEM-XM357 performs direct current measurement up to 100 A AC.

The reference current is 10 A, the minimum current is 0.3 A, and the starting current is 0,04 A.

The maximum current of the measurement path is 100 A, and the manufacturer specifies short-term overload capability at 30 × Imax for 0.01 s.

Measurement type
direct
Maximum current
100 A AC
Reference current
10 A
Minimum current
0,3 A
Starting current
0,04 A

Single- and three-phase networks up to 480 V AC

The nominal measurement voltage is 3 × 230 V AC / 400 V AC.

The voltage range between phase and neutral is 100–277 V AC.

For phase-to-phase measurement, the input range is 173–480 V AC. The meter can operate in single-phase 2-wire and three-phase 3- and 4-wire systems.

Nominal voltage
3 × 230 / 400 V AC
Phase–N
100–277 V AC
Phase–phase
173–480 V AC
Reference frequency
50 / 60 Hz

Energy import and export in four quadrants

The EEM-XM357 is bidirectional meter, so it can record both energy imported and energy exported to the grid.

The manufacturer defines the device as a meter performing four-quadrant measurement.

This makes it possible to record active and reactive energy values while taking the direction of energy flow into account.

Class C according to EN 50470-3

The EEM-XM357 complies with MID directive for measuring instruments.

For active energy, the manufacturer specifies class C according to EN 50470-3 and class 0.5 according to IEC 62053-21.

Reactive energy is measured in class 2 according to IEC 62053-23.

Active energy
Class C
EN 50470-3
Active energy
Class 0.5
IEC 62053-21
Reactive energy
Class 2
IEC 62053-23
Certification
MID / CE

Multi-tariff energy recording via Modbus

The meter has 4 independent energy tariffs.

Tariff handling is performed via Modbus, so the supervisory system can use different energy registers depending on the adopted billing method or operating period.

The function makes it possible to use one meter in more advanced energy monitoring and billing systems.

Number of tariffs
4
Tariff control
via Modbus

RS-485 for supervisory systems

EEM-XM357 has an RS-485 interface with Modbus RTU protocol.

Available transmission speeds are 2400, 4800, 9600, 19 200 and 38 400 bit/s. The factory setting is 9600 bit/s.

The device address can be set from 1 to 247. Odd, even or none parity and one or two stop bits can also be configured.

Interface
RS-485
Protocol
Modbus RTU
Transmission
2400–38 400 bit/s
Factory setting
9600 bit/s
Modbus address
1–247

Fast parameter reading via Modbus

The manufacturer specifies the data update time for active power as 100 ms.

Energy values are updated every 1 second.

This facilitates ongoing use of measurement data in automation and energy monitoring systems.

Two passive, optically isolated outputs

EEM-XM357 has 2 passive, optically isolated pulse outputs.

The maximum switching voltage is 27 V DC, and the maximum current is 27 mA.

For the first output, pulse width and meter constant are configurable. The second output has a pulse width of 100 ms and a constant of 400 imp/kWh.

Number of outputs
2
Type
passive, optically isolated
Max. voltage
27 V DC
Max. current
27 mA
Output 2
400 imp/kWh / 100 ms

Backlit LCD for local reading

The meter is equipped with a LCD display with white backlight.

The maximum displayed energy value is 999999,99 kWh or kVArh.

The display enables local parameter checking without the need to use Modbus communication.

Powered directly from the measurement circuit

The EEM-XM357 does not require a separate auxiliary power supply.

The device is powered directly from the monitored measurement circuit.

Consumption is a maximum of 10 VA / 2 W.

Protection class II and CAT III

EEM-XM357 has protection class II, overvoltage category III and pollution degree 2.

The measurement category is CAT III 300 V.

The rated impulse voltage is 6 kV, while in the EMC data the manufacturer specifies immunity to an impulse voltage of 4 kV.

Protection class
II
Overvoltage category
III
Measurement category
CAT III 300 V
Pollution degree
2

Screw terminals for conductors up to 25 mm²

The main measurement circuit uses screw terminals intended for rigid and flexible conductors with cross-sections from 1,5 to 25 mm².

The stripping length is 12–13 mm, and the required tightening torque is 3,5 Nm.

The remaining connections use terminals for rigid conductors 0,14–2,5 mm² and flexible conductors 0,14–1,5 mm².

Technology
screw
Measurement path
1,5–25 mm²
Tightening torque
3,5 Nm
Other connections
0,14–2,5 mm²

MID measurement at temperatures from −40 to +70°C

The operating temperature range specified for MID use is −40…+70°C.

For UL approval, the manufacturer specifies a range of −40…+65°C, while for the LCD display itself it is 0…+55°C.

Permissible operating humidity is 0 to 90% non-condensing, and the maximum operating altitude is 2000 m.

MID operating temperature
−40…+70°C
Storage temperature
−40…+70°C
Humidity
0–90%
non-condensing
Operating altitude
≤2000 m
Connection protection rating
IP20

Compact 4 HP DIN-rail housing

The EEM-XM357 is intended for horizontal DIN-rail mounting.

Device dimensions are 72 × 100 × 71 mm, and the width corresponds to four modular units.

After mounting on an NS 35/7.5 rail, the depth is 65 mm. The device weight without packaging is 335 g.

4 TE

A width of 72 mm enables compact installation in a standard distribution board.

DIN

Mounting on a standard NS 35/7,5 rail facilitates installation with other equipment.

335 g

The compact design combines a direct 100 A path with communication and billing functions.

Key parameters of Phoenix Contact EEM-XM357

Manufacturer
Phoenix Contact
Model
EEM-XM357
Catalog number
1674511
Family
EMpro
Meter type
bidirectional, four-quadrant
Number of tariffs
4
via Modbus
Current measurement
direct
Max. current
100 A AC
Phase-to-neutral voltage
100–277 V AC
Phase-to-phase voltage
173–480 V AC
Active energy
class C
EN 50470-3
Active energy
class 0.5
IEC 62053-21
Reactive energy
class 2
IEC 62053-23
Certification
MID / CE / cULus Listed
Display
LCD, white backlight
Communication
RS-485 / Modbus RTU
Transmission speed
2400–38 400 bit/s
Modbus address
1–247
Pulse outputs
2
Output parameters
27 V DC / 27 mA max.
Power supply
from the measurement circuit
Consumption
10 VA / 2 W
Protection class
II
Measurement category
CAT III 300 V
MID operating temperature
−40…+70°C
Humidity
0–90%
non-condensing
Operating altitude
≤2000 m
Connection protection rating
IP20
Dimensions
72 × 100 × 71 mm
Modular width
4 TE
Weight
335 g
Mounting
horizontal DIN rail

EEM-XM357 in an energy monitoring system

Electrical installation
up to 480 V AC
→
Direct measurement
up to 100 A AC
→
EEM-XM357
MID measurement + 4 tariffs
→
RS-485
Modbus RTU
→
Higher-level system
PLC / SCADA / energy monitoring
MODEL 3D

EEM-XM357

Ładowanie modelu 3D

Nowości

  • Bestseller New Product
    obraz_2026-07-14_113033157.png GS601 (1).png
    Product code GS601-868M

    E-cigarette smoke sensor

    Manufacturer Milesight
    Gross price $270.60
    incl. %s VAT
    Net price $220.00
    without 23% VAT