Phoenix Contact

ECM-UC-10A-MRTU

Phoenix Contact ECM-UC-10A-MRTU 1191969 is a configurable current transducer designed for measurement of AC, DC and distorted currents. The device offers measurement ranges 0–0,1 A, 0–1 A, 0–5 A and 0–10 A AC/DC, while the maximum configurable input value is 12,5 A AC/DC according to IEC/EN 61010-1.

Version The ECM-UC-10A-MRTU has an interface RS-485 with Modbus RTU protocol and USB-C enabling configuration through the built-in web interface even without an external 24 V DC power supply. The maximum transmission error is 0,5%, the supply range is 9,6–30 V DC, and the compact module with Push-in terminals can operate at temperatures of −40…+60°C.

Go to full description
Availability:
In Stock
Shipping time: 31 dni
USD EUR with VAT without VAT
Price $532.95
incl. 23% VAT

Shipping costs are not included in the price.

szt.

Opis

Produkty powiązane

ECM-UC-10A-MRTU — configurable AC/DC current transducer

Phoenix Contact ECM-UC-10A-MRTU 1191969 is a universal measuring transducer designed for monitoring alternating, direct and distorted currents in automation systems and industrial installations.

The device offers four basic measurement ranges from 0–0.1 A to 0–10 A AC/DC, and the maximum range value can be configured up to 12,5 A AC/DC in accordance with IEC/EN 61010-1.

Version MRTU is equipped with an RS-485 interface with the Modbus RTU protocol. An additional USB-C port enables device configuration through the built-in web interface even when the transducer is not connected to an external 24 V DC power supply.

Wide measurement range, Modbus RTU and USB-C configuration

up to 12.5 A

The configurable measurement range allows one device to be adapted to different current circuits.

AC / DC

One transducer supports direct current, alternating current and distorted waveforms.

Modbus RTU

RS-485 enables digital transmission of measurement values directly to the automation system.

Current measurement in automation and industrial installations

Control cabinets
Electrical distribution boards
Production lines
AC circuits
DC circuits
Load monitoring
PLC systems
Energy monitoring

Four basic AC/DC current ranges

ECM-UC-10A-MRTU can operate with four basic measurement ranges: 0–0.1 A, 0–1 A, 0–5 A and 0–10 A AC/DC.

The minimum input value can be configured in the range from 0 to 100 mA AC/DC.

The maximum input value can be set up to 12.5 A AC/DC according to DIN/EN 61010-1. For applications compliant with UL 61010-1, the maximum range is 10 A.

Range 1
0–0,1 A AC/DC
Range 2
0–1 A AC/DC
Range 3
0–5 A AC/DC
Range 4
0–10 A AC/DC
Max. setting
12,5 A AC/DC
DIN/EN 61010-1

Bidirectional DC current measurement

For direct current, the device enables measurement of both positive and negative current values.

The standard input range is −10…+10 A DC.

The maximum setting range in accordance with DIN/EN 61010-1 can be −12,5…+12,5 A DC, while for UL 61010-1 the −10…+10 A DC range applies.

Standard DC range
−10…+10 A DC
Max. DC range
−12,5…+12,5 A DC
DIN/EN 61010-1

Measurement of AC, DC and non-sinusoidal signals

ECM-UC-10A-MRTU is designed not only for standard AC and DC waveforms, but also for measurement of distorted currents.

This allows the transducer to be used in circuits with power electronics, controllers, power regulators and other loads generating non-sinusoidal current waveforms.

The configurable frequency band additionally allows the measurement characteristics to be adapted to a specific application.

Configurable measurement bandwidth up to 1000 Hz

The device allows selection of several measurement frequency ranges.

Available ranges are 0–100 Hz, 0–200 Hz, 0–500 Hz and 0–1000 Hz.

This allows the transducer to be used both in standard 50/60 Hz circuits and in applications with higher signal frequencies.

Range 1
0–100 Hz
Range 2
0–200 Hz
Range 3
0–500 Hz
Range 4
0–1000 Hz

Maximum transmission error 0.5%

The maximum transmission error of the ECM-UC-10A-MRTU is 0.5% of nominal range value under nominal conditions.

The maximum temperature coefficient is less than 0,03%/K.

The parameters enable stable current monitoring in industrial applications operating over a wide ambient temperature range.

Transmission error
max. 0.5%
Temperature coefficient
<0,03%/K

Response time from 20 ms

The 10–90% step response time during AC/DC measurement is 200 ms.

For direct current measurement, the response time can be 20 ms.

This allows both steady-state values and relatively fast load changes in the monitored circuit to be recorded.

AC/DC response
200 ms
10–90%
DC response
20 ms
10–90%

Reserve capacity during short-term current increases

ECM-UC-10A-MRTU has a continuous overload capacity of 2 × IN.

Surge withstand is 10 × IN.

This provides additional reserve in circuits where short-term current values exceeding the configured measurement range may occur.

Overload capacity
2 × IN
Surge withstand
10 × IN

RS-485 for integration with automation systems

Version ECM-UC-10A-MRTU is equipped with an interface RS-485 with Modbus RTU protocol.

The default communication configuration uses Modbus address 1, 8 data bits, even parity and 1 stop bit.

The default transmission speed is 19 200 Bd. This allows measurement data to be transmitted directly to PLC controllers, data concentrators or other devices supporting Modbus RTU.

Interface
RS-485
Protocol
Modbus RTU
Default address
1
Speed
19 200 Bd
Format
8E1

USB-C and built-in web interface

ECM-UC-10A-MRTU can be configured via USB-C port and integrated Web Based Management.

After connecting the device to a computer, the configuration interface can be opened in a standard web browser.

For configuration via USB-C external 24 V DC power supply is not required, and the default WBM interface address is 192.168.128.1.

USB-C

The standard port enables quick connection of the device to a computer.

WBM

The transducer parameters can be changed using the browser-based interface.

Without 24 V DC

When configuring via USB-C, there is no need to connect an external power supply to the device.

Wide range 9.6–30 V DC

The nominal supply voltage of the ECM-UC-10A-MRTU is 24 V DC.

The permissible supply range is from 9.6 to 30 V DC.

The maximum power consumption of the device is 2 W at 30 V DC.

Nominal supply
24 V DC
Supply range
9,6–30 V DC
Power consumption
≤2 W
at 30 V DC

Safe isolation according to IEC/EN 61010-1

ECM-UC-10A-MRTU provides safe isolation according to IEC/EN 61010-1.

The test voltage between input and output and between input and the power-supply circuit is 4 kV AC for 60 seconds.

Between the output and the power supply, the test voltage is 2 kV AC. The rated insulation voltage to earth is 300 V AC.

Isolation
safe isolation
Input / output
4 kV AC
Input / power supply
4 kV AC
Output / power supply
2 kV AC
Overvoltage category
III / 300 V

Fast Push-in terminals

Electrical connections of the device are made using Push-in terminals.

Solid and flexible conductors with cross-sections from 0.2 to 2.5 mm².

The recommended stripping length is 10 mm.

Technology
Push-in
Solid conductor
0,2–2,5 mm²
Flexible conductor
0,2–2,5 mm²
AWG
24–13

From −40 to +60°C and altitude up to 4000 m

Operating temperature
−40…+60°C
Storage / transport
−40…+85°C
Humidity
≤95%
non-condensing
Operating altitude
≤4000 m
Protection rating
IP20

Narrow 22.6 mm housing for DIN rail

ECM-UC-10A-MRTU is only 22,6 mmwide, so it takes up little space in the control cabinet.

Device dimensions are 22,6 × 106,7 × 113,8 mm. After installation on an NS 35/7.5 rail, the depth is approximately 114.5 mm.

The manufacturer permits installation of the device in both vertical and horizontal positions.

22,6 mm

The narrow design allows efficient use of the space available in the distribution board.

DIN

The module is designed for mounting on a standard NS 35/7.5 rail.

IP20

The housing is intended for installation inside a suitably protected control cabinet or distribution board.

Design for industrial applications

ECM-UC-10A-MRTU uses safe isolation in accordance with IEC/EN 61010-1 and meets the requirements of IEC 61010-2-030.

Electromagnetic immunity complies with EN 61000-6-2, while interference emission complies with EN 61000-6-4.

The product has CE conformity and cULus approvals for the US and Canadian markets.

Key parameters of Phoenix Contact ECM-UC-10A-MRTU

Manufacturer
Phoenix Contact
Model
ECM-UC-10A-MRTU
Catalog number
1191969
Product type
current measurement transducer
Current type
AC / DC / distorted
AC input range
0–10 A AC
DC input range
−10…+10 A DC
Measurement ranges
0,1 / 1 / 5 / 10 A AC/DC
Max. setting range
12,5 A AC/DC
DIN/EN 61010-1
Frequency
up to 1000 Hz
Transmission error
max. 0.5%
Temperature coefficient
<0,03%/K
AC/DC response
200 ms
DC response
20 ms
Overload capacity
2 × IN
Surge withstand
10 × IN
Interface
RS-485
Protocol
Modbus RTU
Default Modbus address
1
Transmission speed
19 200 Bd
Modbus format
8E1
Configuration
USB-C / WBM
WBM address
192.168.128.1
Nominal supply
24 V DC
Supply range
9,6–30 V DC
Power consumption
≤2 W
at 30 V DC
Isolation
safe according to IEC/EN 61010-1
Overvoltage category
III / 300 V
Connections
Push-in
Conductor cross-section
0,2–2,5 mm²
Operating temperature
−40…+60°C
Storage temperature
−40…+85°C
Humidity
≤95%
non-condensing
Operating altitude
≤4000 m
Protection rating
IP20
Dimensions
22,6 × 106,7 × 113,8 mm
Depth on rail
114,5 mm
Weight
113,5 g
Mounting
vertical or horizontal, DIN rail

ECM-UC-10A-MRTU in a measurement system

Electrical circuit
AC / DC current up to 12.5 A
→
ECM-UC-10A-MRTU
current measurement and conversion
→
RS-485
Modbus RTU
→
Higher-level system
PLC / SCADA / monitoring
MODEL 3D

ECM-UC-10A-MRTU

Ładowanie modelu 3D

Nowości

  • Bestseller New Product
    obraz_2026-07-14_113033157.png GS601 (1).png
    Product code GS601-868M

    E-cigarette smoke sensor

    Manufacturer Milesight
    Gross price $270.60
    incl. %s VAT
    Net price $220.00
    without 23% VAT