Phoenix Contact

ECM-UC-10A-UI

Phoenix Contact ECM-UC-10A-UI 1136504 is a configurable measuring transducer designed for measurement of alternating, direct and distorted currents. The device offers four measurement ranges 0–0,1 A, 0–1 A, 0–5 A and 0–10 A AC/DC, while the maximum configurable input value is 12,5 A AC/DC according to DIN/EN 61010-1. The maximum transmission error is 0,5%, and the measurement bandwidth can be set up to 1000 Hz.

Version The ECM-UC-10A-UI has a configurable analog voltage or current output, including 0–10 V, ±10 V, 0–20 mA and 4–20 mA. Configuration is performed via USB-C and the built-in web interface even without an external 24 V DC power supply. The supply range is 9,6–30 V DC, the device has Push-in terminals and can operate at temperatures of −40…+60°C.

Go to full description
Availability:
In Stock
Shipping time: 31 dni
USD EUR with VAT without VAT
Price $491.36
incl. 23% VAT

Shipping costs are not included in the price.

szt.

Opis

Produkty powiązane

ECM-UC-10A-UI — configurable current transducer up to 12,5 A

Phoenix Contact ECM-UC-10A-UI 1136504 is a universal measuring transducer designed for monitoring alternating, direct and distorted currents in automation systems and industrial installations.

The device offers four basic measurement ranges from 0–0,1 A to 0–10 A AC/DC, while the maximum configurable input value can be 12,5 A AC/DC according to DIN/EN 61010-1.

Version The UI converts the measured value into a standard analog voltage or current signal. A wide selection of output ranges makes it possible to adapt the device to analog inputs of PLC controllers, I/O modules, SCADA systems and other measurement systems.

One transducer for multiple AC and DC current ranges

up to 12,5 A

Configurable ranges allow one device to be adapted to different measurement circuits.

AC / DC

The transducer supports alternating current, direct current and distorted waveforms.

U / I

Configurable voltage or current output simplifies integration with standard analog inputs.

Current monitoring in automation systems

Control cabinets
Electrical distribution boards
Production lines
Motors and drives
AC circuits
DC circuits
Load monitoring
Machine diagnostics

Four basic ranges from 100 mA to 10 A

The ECM-UC-10A-UI can operate in four basic ranges: 0–0,1 A, 0–1 A, 0–5 A and 0–10 A AC/DC.

The minimum input-range value can be set from 0 to 100 mA AC/DC.

The maximum value can be configured up to 12.5 A AC/DC according to DIN/EN 61010-1. For applications compliant with UL 61010-1, the maximum range is 10 A.

Range 1
0–0,1 A AC/DC
Range 2
0–1 A AC/DC
Range 3
0–5 A AC/DC
Range 4
0–10 A AC/DC
Max. setting
12,5 A AC/DC
DIN/EN 61010-1

Bidirectional DC current measurement

For direct current, the ECM-UC-10A-UI enables measurement of both positive and negative values.

The standard input range is −10…+10 A DC.

The maximum configurable range according to DIN/EN 61010-1 can be −12,5…+12,5 A DC, allowing the device to also represent current-flow direction.

Standard DC range
−10…+10 A DC
Max. DC range
−12,5…+12,5 A DC
DIN/EN 61010-1

Measurement of AC, DC and non-sinusoidal signals

The ECM-UC-10A-UI is designed for measuring alternating, direct and distorted currents.

This makes it possible to use the transducer also in circuits with power-electronic equipment, power controllers, converters and other loads where the current waveform differs from an ideal sine wave.

The configurable frequency bandwidth allows the measurement characteristic to be further adapted to a specific application.

Configurable measurement bandwidth up to 1000 Hz

Phoenix Contact allows several measurement-frequency ranges to be selected.

Available ranges are 0–100 Hz, 0–200 Hz, 0–500 Hz and 0–1000 Hz.

As a result, the device can operate both in conventional 50/60 Hz installations and in applications containing higher-frequency components.

Range 1
0–100 Hz
Range 2
0–200 Hz
Range 3
0–500 Hz
Range 4
0–1000 Hz

Maximum transmission error 0,5%

The maximum transmission error of the ECM-UC-10A-UI is 0,5% of the nominal range value under nominal conditions.

The maximum temperature coefficient is less than 0,02%/K.

These parameters enable stable current monitoring even with temperature changes occurring in industrial control cabinets.

Transmission error
max. 0,5%
Temperature coefficient
<0,02%/K

Response time from 20 ms

The 10–90% step response time during AC/DC measurement is 200 ms.

For DC measurement, the response time is 20 ms.

This makes it possible to record both steady load values and relatively fast current changes.

AC/DC response
200 ms
10–90%
DC response
20 ms
10–90%

Resistance to measurement-range overload

The ECM-UC-10A-UI has continuous overload capability of 2 × IN.

Surge withstand is 10 × IN.

This provides additional margin during short-term current increases in the monitored circuit.

Overload capacity
2 × IN
Surge withstand
10 × IN

Wide selection of voltage and current signals

The measured value can be transmitted to the control system through a configurable voltage or current output.

Available voltage ranges are 0–10 V, 0–5 V, 1–5 V, 2–10 V, −10…+10 V and −5…+5 V.

The device also supports reversed characteristics 10…−10 V, 5…−5 V, 10–0 V and 5–0 V.

Voltage output
0–10 V / 0–5 V / 1–5 V / 2–10 V
Bipolar output
−10…+10 V / −5…+5 V
Output load
>10 kΩ

Standard 0–20 mA and 4–20 mA signals

The analog output can also be configured as a standard current signal.

Available characteristics are 0–20 mA and 4–20 mA, as well as reversed ranges 20–0 mA and 20–4 mA.

The maximum load resistance of the current output is below 500 Ω.

Standard output
0–20 mA / 4–20 mA
Reversed output
20–0 mA / 20–4 mA
Load
<500 Ω

USB-C and built-in web interface

The ECM-UC-10A-UI can be configured via the USB-C interface and integrated Web Based Management.

For configuration via USB-C an external 24 V DC power supply is not required, allowing settings to be prepared even before installing the device in the cabinet.

The default WBM interface address is 192.168.128.1.

USB-C

The standard interface enables quick connection of the transducer to a computer.

WBM

Parameter configuration is performed through an interface accessible in a web browser.

Without 24 V DC

During USB-C configuration, there is no need to connect an external power supply to the transducer.

Wide 9,6–30 V DC range

The nominal supply voltage of the device is 24 V DC.

The nominal supply range covers 12–24 V DC with −20% / +25% tolerance, while the full operating range is 9,6–30 V DC.

Maximum power consumption is 2,3 W at 30 V DC.

Nominal supply
24 V DC
Nominal range
12–24 V DC
−20% / +25%
Operating range
9,6–30 V DC
Power consumption
≤2,3 W
at 30 V DC

Safe isolation according to IEC/EN 61010-1

The ECM-UC-10A-UI provides safe isolation according to IEC/EN 61010-1.

The test voltage between input and output and between input and power supply is 4 kV AC at 50 Hz for 60 seconds.

Between output and power supply, the test voltage is 2 kV AC. The overvoltage and measurement category of the device is III at 300 V.

Isolation
safe isolation
Input / output
4 kV AC
Input / power supply
4 kV AC
Output / power supply
2 kV AC

Fast Push-in terminals

The device electrical connections are made using Push-in terminals.

Solid and flexible conductors with cross-section from 0.2 to 2.5 mm².

The recommended conductor stripping length is 10 mm.

Technology
Push-in
Solid conductor
0,2–2,5 mm²
Flexible conductor
0,2–2,5 mm²
AWG
24–13

Operation from −40 to +60°C

Operating temperature
−40…+60°C
Storage / transport
−40…+85°C
Humidity
≤95%
non-condensing
Operating altitude
≤4000 m
Protection rating
IP20

Compact 22,6 mm DIN-rail module

The ECM-UC-10A-UI is only 22,6 mmwide, enabling efficient use of space in the control cabinet.

Device dimensions are 22,6 × 106,7 × 113,8 mm. After mounting on an NS 35/7,5 rail, the depth is 114,5 mm.

The manufacturer permits installation of the device in both vertical and horizontal positions.

22,6 mm

The narrow design reduces the amount of space required on the mounting rail.

DIN

The device is prepared for installation on a standard NS 35/7,5 rail.

IP20

The housing is intended for installation inside a suitably protected cabinet or distribution board.

Key parameters of Phoenix Contact ECM-UC-10A-UI

Manufacturer
Phoenix Contact
Model
ECM-UC-10A-UI
Catalog number
1136504
Product type
current measuring transducer
Current type
AC / DC / distorted
AC range
0–10 A AC
DC range
−10…+10 A DC
Measurement ranges
0,1 / 1 / 5 / 10 A AC/DC
Max. range
12,5 A AC/DC
DIN/EN 61010-1
Max. DC range
−12,5…+12,5 A DC
Measurement bandwidth
up to 1000 Hz
Transmission error
max. 0.5%
Temperature coefficient
<0,02%/K
AC/DC response
200 ms
DC response
20 ms
Overload capacity
2 × IN
Surge withstand
10 × IN
Voltage output
e.g. 0–10 V / 0–5 V / 2–10 V / ±10 V
Current output
0–20 mA / 4–20 mA
U output load
>10 kΩ
I output load
<500 Ω
Configuration
USB-C / WBM
WBM address
192.168.128.1
Nominal supply
24 V DC
Supply range
9,6–30 V DC
Power consumption
≤2,3 W
at 30 V DC
Isolation
safe according to IEC/EN 61010-1
Measurement category
III / 300 V
Connections
Push-in
Conductor cross-section
0,2–2,5 mm²
Operating temperature
−40…+60°C
Storage temperature
−40…+85°C
Humidity
≤95%
non-condensing
Operating altitude
≤4000 m
Protection rating
IP20
Dimensions
22,6 × 106,7 × 113,8 mm
Depth on rail
114,5 mm
Weight
149,6 g
Mounting
vertical or horizontal, DIN rail

ECM-UC-10A-UI in a measurement system

Electrical circuit
AC / DC current up to 12,5 A
→
ECM-UC-10A-UI
current measurement and conversion
→
Analog signal
e.g. 0–10 V / 4–20 mA
→
Higher-level system
PLC / SCADA / monitoring
MODEL 3D

ECM-UC-10A-UI

Ładowanie modelu 3D

Nowości

  • Bestseller New Product
    obraz_2026-07-14_113033157.png GS601 (1).png
    Product code GS601-868M

    E-cigarette smoke sensor

    Manufacturer Milesight
    Gross price $270.60
    incl. %s VAT
    Net price $220.00